代码暂存 使用Lwrb库优化4G上报多条数据时的冲突问题
This commit is contained in:
parent
e3016cca9c
commit
7d7f2f1dab
|
@ -3,7 +3,8 @@
|
|||
|
||||
|
||||
#include "CH58x_common.h"
|
||||
|
||||
#include "lwrb.h"
|
||||
#include "bsp_valve.h"
|
||||
/*4G 친욥왠齡多신*/
|
||||
#define ENABLE_3_8_V GPIO_Pin_3 //PB3
|
||||
|
||||
|
@ -110,7 +111,7 @@ static void BSP_Ml307_Power_Off(void);
|
|||
|
||||
|
||||
void BSP_Ml307r_Init(void);
|
||||
void Iot_Send_Data(void);
|
||||
void Iot_Send_Data(TeFrameCmd cmd);
|
||||
void Ml307r_Loop(void);
|
||||
void BSP_Module_Emergency_Send(uint8_t* data, uint8_t len);
|
||||
void BSP_ML307_StartTimeoutTimer(void);
|
||||
|
@ -120,6 +121,15 @@ static void BSP_Read_Module(void);
|
|||
static void BSP_simcom_init(void);
|
||||
static void BSP_Get_Module_Info(void);
|
||||
static void BSP_Module_Connect_CtWing(void);
|
||||
|
||||
// 状态上报请求结构体
|
||||
typedef struct {
|
||||
TeFrameCmd cmd; // 命令类型
|
||||
} TsIotSendRequest;
|
||||
|
||||
// 声明状态上报队列
|
||||
extern lwrb_t iot_send_queue;
|
||||
extern uint8_t iot_send_queue_buffer[sizeof(TsIotSendRequest) * 5]; // 可以存储5个请求
|
||||
#endif //!@__BSP_ML307R_H__
|
||||
|
||||
|
||||
|
|
|
@ -42,57 +42,6 @@ void ADC_GPIO_Init(void)
|
|||
R8_ADC_CFG |= RB_ADC_POWER_ON;
|
||||
}
|
||||
|
||||
|
||||
// void Send_Low_Battery_Message(float vbat)
|
||||
// {
|
||||
// char json_buffer[300];
|
||||
// char time_str[20] = {0};
|
||||
// snprintf(json_buffer, sizeof(json_buffer),
|
||||
// "{"
|
||||
// "\"device\":{"
|
||||
// "\"id\":\"SCV001\","
|
||||
// "\"type\":\"SelfClosingValve\","
|
||||
// "\"time\":\"%s\""
|
||||
// "},"
|
||||
// "\"status\":\"closed\","
|
||||
// "\"fault\":{"
|
||||
// "\"lowBattery\":true,"
|
||||
// "\"commError\":false,"
|
||||
// "\"code\":1001"
|
||||
// "},"
|
||||
// "\"monitor\":{"
|
||||
// "\"pressure\":0.8,"
|
||||
// "\"voltage\":%.2f,"
|
||||
// "\"lowVoltage\":true"
|
||||
// "},"
|
||||
// "\"network\":{"
|
||||
// "\"sinr\":15.2,"
|
||||
// "\"rsrp\":-95.5,"
|
||||
// "\"signal\":4"
|
||||
// "},"
|
||||
// "\"standards\":{"
|
||||
// "\"iotId\":\"IoT-SCV-12345\""
|
||||
// "}"
|
||||
// "}",
|
||||
// time_str, vbat);
|
||||
// BSP_Module_Emergency_Send((uint8_t*)json_buffer, strlen(json_buffer));
|
||||
// logDebug("Send low battery message: %s\n", json_buffer);
|
||||
// }
|
||||
|
||||
// // ´¦Àíµç³ØµçѹµÍʼþ
|
||||
// void Handle_Low_Battery(float vbat)
|
||||
// {
|
||||
// if (!vbat_low_flag) {
|
||||
// VALVE_CLOSE();
|
||||
// LED_VALVE_CLOSE;
|
||||
// Send_Low_Battery_Message(vbat);
|
||||
// vbat_low_flag = 1;
|
||||
// logDebug("Voltage is too low (%.2fV),Close valve\n", vbat);
|
||||
// }
|
||||
// LED_VBAT_OPEN;
|
||||
// DelayMs(100);
|
||||
// }
|
||||
|
||||
uint16_t VBAT_ProcessEvent(uint8_t task_id, uint16_t events)
|
||||
{
|
||||
if (events & VBAT_EVT_START)
|
||||
|
|
|
@ -1051,7 +1051,6 @@ uint16_t Check_ProcessEvent(uint8_t task_id, uint16_t events)
|
|||
if (motor_flag == 1)
|
||||
{
|
||||
motor_flag = 0;
|
||||
LED_VALVE_OPEN;
|
||||
BSP_VALVE_Open(kValveCmdManualOpen); // 使用普通开阀命令
|
||||
keydown_flag = 1;
|
||||
IotFlag_t.Valve_Open_flag = 1;
|
||||
|
@ -1061,7 +1060,6 @@ uint16_t Check_ProcessEvent(uint8_t task_id, uint16_t events)
|
|||
else if (motor_flag == 2)
|
||||
{
|
||||
motor_flag = 0;
|
||||
LED_VALVE_CLOSE;
|
||||
|
||||
// 直接使用普通关阀命令
|
||||
BSP_VALVE_Close(kValveCmdManualClose);
|
||||
|
|
|
@ -12,13 +12,17 @@
|
|||
#include "time.h"
|
||||
#include <stdlib.h>
|
||||
#include "cJSON.h"
|
||||
#include "bsp_valve.h"
|
||||
#include "bsp_adc.h"
|
||||
|
||||
#undef LOG_ENABLE
|
||||
#define LOG_ENABLE 1
|
||||
|
||||
IotFlagStruct IotFlag_t;
|
||||
|
||||
// 创建环形缓冲区用于存储IoT发送请求
|
||||
lwrb_t iot_send_queue;
|
||||
uint8_t iot_send_queue_buffer[sizeof(TsIotSendRequest) * 5] = {0};
|
||||
|
||||
#define ML307_PERIODIC_EVT (0x0001 << 0)
|
||||
|
||||
|
||||
|
@ -722,15 +726,24 @@ static void BSP_SendMessage(void)
|
|||
|
||||
void BSP_ML307_SendMessage(void)
|
||||
{
|
||||
// 根据系统状态确定命令类型
|
||||
TeFrameCmd cmd = kCmdData; // 默认为数据命令
|
||||
// 默认命令类型
|
||||
TeFrameCmd cmd = kCmdData;
|
||||
|
||||
if (gValveData.switch_status == kClosed)
|
||||
{
|
||||
cmd = gValveCloseReason;
|
||||
}else
|
||||
{
|
||||
cmd = gValveOpenReason;
|
||||
// 从队列中读取一个请求
|
||||
TsIotSendRequest request;
|
||||
if (lwrb_get_full(&iot_send_queue) >= sizeof(request)) {
|
||||
lwrb_read(&iot_send_queue, &request, sizeof(request));
|
||||
cmd = request.cmd;
|
||||
logDebug("Get command type: %d\r\n", cmd);
|
||||
} else {
|
||||
// 如果队列为空,则使用默认逻辑
|
||||
if (gValveData.switch_status == kClosed)
|
||||
{
|
||||
cmd = gValveCloseReason;
|
||||
}else
|
||||
{
|
||||
cmd = gValveOpenReason;
|
||||
}
|
||||
}
|
||||
|
||||
// 生成JSON数据
|
||||
|
@ -744,7 +757,7 @@ void BSP_ML307_SendMessage(void)
|
|||
logDebug("json_data len %d\r\n", strlen(json_data));
|
||||
BSP_SendMessage();
|
||||
} else {
|
||||
logDebug("JSON数据内存分配失败!\n");
|
||||
logDebug("JSON Memory failure!\n");
|
||||
IotFlag_t.send_error_flag = 1;
|
||||
}
|
||||
}
|
||||
|
@ -1051,33 +1064,31 @@ static void BSP_Iot_Loop(void)
|
|||
{
|
||||
logDebug("send_complete_into_stop\r\n");
|
||||
IotFlag_t.send_complete_flag = 0;
|
||||
state = 0;
|
||||
|
||||
// 检查指针是否为NULL后再释放,避免重复释放
|
||||
if(json_data != NULL) {
|
||||
tmos_msg_deallocate((uint8_t *)json_data);
|
||||
json_data = NULL;
|
||||
}
|
||||
MultiTimerStart(&Multi_StopTask_t, STOP_TASK_INTERVAL_TIME, StopTask_CallBack, NULL); //关闭
|
||||
|
||||
// 检查队列中是否还有待发送的请求
|
||||
if (lwrb_get_full(&iot_send_queue) >= sizeof(TsIotSendRequest)) {
|
||||
logDebug("The queue has data to be sent, continue\r\n");
|
||||
IotFlag_t.ModInfo_success_flag = 1;
|
||||
state = 5; // 直接跳转到发送状态
|
||||
} else {
|
||||
logDebug("send finish\r\n");
|
||||
state = 0;
|
||||
MultiTimerStart(&Multi_StopTask_t, STOP_TASK_INTERVAL_TIME, StopTask_CallBack, NULL); //关闭
|
||||
}
|
||||
}else
|
||||
{
|
||||
// if (IotFlag_t.Loop_count_flag > 2)
|
||||
// {
|
||||
// logDebug("Loop_count_flag_end %d\r\n",IotFlag_t.Loop_count_flag);
|
||||
state = 0;
|
||||
IotFlag_t.Iot_Retry_flag = 0;
|
||||
IotFlag_t.module_init_flag = 0;
|
||||
MultiTimerStart(&Multi_StopTask_t, STOP_TASK_INTERVAL_TIME, StopTask_CallBack, NULL);
|
||||
// }
|
||||
// if((IotFlag_t.Iot_Retry_flag == 0)&&(IotFlag_t.Loop_count_flag < 3))
|
||||
// {
|
||||
// logDebug("error_into_loop\r\n");
|
||||
// logDebug("Loop_count_flag %d\r\n",IotFlag_t.Loop_count_flag);
|
||||
// BSP_Ml307_Power_Off(); //关机
|
||||
// MultiTimerStart(&Multi_Loop_t, LOOP_INTERVAL_TIME, Loop_CallBack, NULL);
|
||||
// IotFlag_t.Iot_Retry_flag = 1;
|
||||
// }
|
||||
state = 0;
|
||||
IotFlag_t.Iot_Retry_flag = 0;
|
||||
IotFlag_t.module_init_flag = 0;
|
||||
MultiTimerStart(&Multi_StopTask_t, STOP_TASK_INTERVAL_TIME, StopTask_CallBack, NULL);
|
||||
}
|
||||
break;
|
||||
break;
|
||||
}
|
||||
}
|
||||
|
||||
|
@ -1105,6 +1116,8 @@ void BSP_Ml307r_Init(void)
|
|||
{
|
||||
if(IotFlag_t.Date_Sending_flag == 0)
|
||||
{
|
||||
// 初始化状态上报队列
|
||||
lwrb_init(&iot_send_queue, iot_send_queue_buffer, sizeof(iot_send_queue_buffer));
|
||||
BSP_UART1_Init();
|
||||
Ml307r_Gpio_Init();
|
||||
ml307r_obj = at_obj_create(&at_adapter);//Create AT communication object
|
||||
|
@ -1125,28 +1138,36 @@ void BSP_Ml307r_Init(void)
|
|||
}
|
||||
}
|
||||
|
||||
void Iot_Send_Data(void)
|
||||
void Iot_Send_Data(TeFrameCmd cmd)
|
||||
{
|
||||
if(IotFlag_t.Date_Sending_flag == 0)
|
||||
{
|
||||
logDebug("Iot_Send_Data!!!\r\n");
|
||||
BSP_UART1_Init();
|
||||
Ml307r_Gpio_Init();
|
||||
logDebug("Ml307r_Init_Finish!!!\r\n");
|
||||
if(ml307r_obj != NULL)
|
||||
// 创建请求结构体
|
||||
TsIotSendRequest request;
|
||||
request.cmd = cmd;
|
||||
|
||||
// 将请求添加到队列
|
||||
if (lwrb_write(&iot_send_queue, &request, sizeof(request)) == sizeof(request)) {
|
||||
logDebug("add to the queue\r\n");
|
||||
|
||||
// 如果当前没有发送任务在进行,则启动发送流程
|
||||
if(IotFlag_t.Date_Sending_flag == 0)
|
||||
{
|
||||
IotFlag_t.Date_Sending_flag = 1;
|
||||
IotFlag_t.module_init_flag = 1;
|
||||
BSP_BlockSleep();
|
||||
ml307_task_id = TMOS_ProcessEventRegister(Ml307r_Handle);
|
||||
// tmos_set_event(ml307_task_id, ML307_PERIODIC_EVT);
|
||||
tmos_start_task(ml307_task_id, ML307_PERIODIC_EVT, MS1_TO_SYSTEM_TIME(300)); //电流稳定后再启动模组
|
||||
}else
|
||||
{
|
||||
BSP_Ml307r_Init();
|
||||
BSP_UART1_Init();
|
||||
Ml307r_Gpio_Init();
|
||||
logDebug("Ml307r_Init_Finish!!!\r\n");
|
||||
if(ml307r_obj != NULL)
|
||||
{
|
||||
IotFlag_t.Date_Sending_flag = 1;
|
||||
IotFlag_t.module_init_flag = 1;
|
||||
BSP_BlockSleep();
|
||||
ml307_task_id = TMOS_ProcessEventRegister(Ml307r_Handle);
|
||||
tmos_start_task(ml307_task_id, ML307_PERIODIC_EVT, MS1_TO_SYSTEM_TIME(300));
|
||||
}else
|
||||
{
|
||||
BSP_Ml307r_Init();
|
||||
}
|
||||
}
|
||||
}else
|
||||
{
|
||||
logDebug("ERROR ,Iot_Send_Data!!!\r\n");
|
||||
} else {
|
||||
logDebug("The queue is full\r\n");
|
||||
lwrb_reset(&iot_send_queue);
|
||||
}
|
||||
}
|
||||
|
|
|
@ -371,9 +371,12 @@ static uint16_t VAVLE_Task_ProcessEvent(uint8_t task_id, uint16_t events) // 阀
|
|||
|
||||
tmos_set_event(Peripheral_TaskID, SBP_REPLY_CMD_EVT);
|
||||
|
||||
BSP_RequestSleep();
|
||||
if (IotFlag_t.Date_Sending_flag == 0)
|
||||
{
|
||||
BSP_RequestSleep();
|
||||
}
|
||||
logDebug("VAVLE_CLOSE_END_EVT");
|
||||
Iot_Send_Data();
|
||||
Iot_Send_Data(gValveCloseReason);
|
||||
return (events ^ VAVLE_CLOSE_END_EVT);
|
||||
}
|
||||
|
||||
|
@ -424,9 +427,12 @@ static uint16_t VAVLE_Task_ProcessEvent(uint8_t task_id, uint16_t events) // 阀
|
|||
gValveOpenReason = kCmdOpenVavle;
|
||||
|
||||
tmos_set_event(Peripheral_TaskID, SBP_REPLY_CMD_EVT);
|
||||
BSP_RequestSleep();
|
||||
if (IotFlag_t.Date_Sending_flag == 0)
|
||||
{
|
||||
BSP_RequestSleep();
|
||||
}
|
||||
|
||||
Iot_Send_Data();
|
||||
Iot_Send_Data(gValveOpenReason);
|
||||
// 启动微泄漏检测
|
||||
startMicroLeakDetection();
|
||||
|
||||
|
@ -628,7 +634,7 @@ uint8_t BSP_VALVE_Close(TeFrameCmd close_reason)
|
|||
|
||||
// 设置关阀原因
|
||||
gValveCloseReason = close_reason;
|
||||
|
||||
LED_VALVE_CLOSE;
|
||||
// 触发关阀事件
|
||||
tmos_set_event(vavle_task_id, VAVLE_CLOSE_START_EVT);
|
||||
|
||||
|
@ -702,7 +708,7 @@ uint8_t BSP_VALVE_Open(TeFrameCmd open_reason)
|
|||
return 2;
|
||||
}
|
||||
gValveOpenReason = open_reason;
|
||||
|
||||
LED_VALVE_OPEN;
|
||||
// 触发开阀事件
|
||||
tmos_set_event(vavle_task_id, VAVLE_OPEN_START_EVT);
|
||||
|
||||
|
|
Loading…